Auto Chemistry Analyzer Manufacturer,Supplier and Exporter in India

Auto Chemistry Analyzer

Product Code : PHLP-11349
Pharmacy Lab Equipment is a leading Auto Chemistry Analyzer Manufacturer,and suppliers in India, Auto Chemistry Analyzer Manufacturer,and suppliers in South Africa.Auto Chemistry Analyzer Suppliers in Mozambique,Auto Chemistry Analyzer in Supplier Kenya, Argentina (Buenos Aires), Australia (Canberra), Austria (Vienna), Bolivia (Sucre), Botswana (Gaborone), Brazil (Brasília), Brunei (Bandar Seri Begawan), Bulgaria (Sofia), Burkina Faso (Ouagadougou), Burundi (Gitega), Cape Verde (Praia), Central African Republic (Bangui), Chad (N'Djamena), Chile (Santiago), Colombia (Bogota), Comoros (Moroni), Congo (Kinshasa), Costa Rica (San José), Croatia (Zagreb) nda, Seychelles, Tanzania and Uganda.

Technical Features

Type

Bench-top, Discrete, Fully automatic

Vertical, Discrete, Fully automatic

Throughput

200T/H

400T/H

Analysis Method

End-point, Fixed-time, Rate

End-point, kinetic, Two-point

Sample Positions

49 sample positions

120 sample positions

Reagent Positions

56 refrigerated reagent positions

90 pcs (With refrigerated function)

Sample Volume

2ul ~70ul (0.1ul stepping)

2-30ul,0.1"l step

Reagent Volume

R1&R2:20ul ~350ul (1ul stepping)

20-300μl,1μl step

Probe cleaning

Automatic washing both interior and exterior

Automatic washing both interior and exterior

Reagent tray cooling

Continuous 2°C~8°C cooling within 24 hours

Continuous 2°C~8°C cooling within 24 hours

Reaction Time

10 minutes

10 minutes

Temperature Control

37°C±0.1°C, with online software monitor the temperature

37±0.1°C, automatic heating

Cuvettes

120 reusable reaction cuvettes (optical path length 6mm)

90 reusable reaction cuvettes

Mixer probe

After adding reagent and sample, blending immediately

--

Washing

After finish testing, washing probe wash cuvettes automatically

After finish testing, washing probe wash cuvettes automatically

Light Source

12V/30W halogen-tungsten lamp, 2000 hours

Halogen-tungsten lamp

Spectroscopic methods

Post light split detection technique

--

Wavelength Range

340,405,450,510,546,578,630,700nm

340-700nm,8 wavelengths, (4 positions are optional)

Linear Range

0.000~3.000Abs

0.0001Abs

Power Supply

110/220V±10%, 50/60Hz

AC110/220V, ±10%, 50/60Hz,1000VA

Package Size (W*D*H)

1120*730*980mm

1220*1340*890mm

Gross Weight

185kg

200Kg


   