Auto Chemistry Analyzer Manufacturer,Supplier and Exporter in India

Auto Chemistry Analyzer

Product Code : PHLP-11349
Pharmacy Lab Equipment is a leading Auto Chemistry Analyzer Manufacturer,suppliers and Exporter in India, Auto Chemistry Analyzer Uruguay (Montevideo), Auto Chemistry Analyzer Uzbekistan (Tashkent), Auto Chemistry Analyzer Venezuela (Caracas), Auto Chemistry Analyzer Vietnam (Hanoi), Auto Chemistry Analyzer Yemen (Sana'a), Auto Chemistry Analyzer Zambia (Lusaka), Zimbabwe (Harare), Eswatini (Mbabane) (Lobamba), Ethiopia (Addis Ababa), Fiji (Suva), Gabon (Libreville), Gambia (Banjul), Georgia (Tbilisi), Ghana (Accra), India (Delhi, Mumbai, Kolkatta, Chennai), Indonesia (Jakarta), Iraq (Baghdad), Ivory Coast (Yamoussoukro), Jamaica (Kingston), Jordan (Amman), Kazakhstan (Astana), Kenya (Nairobi), Kiribati (Tarawa), Kosovo (Pristina), Kuwait (Kuwait City), Kyrgyzstan (Bishkek), Laos (Vientiane), Latvia (Riga), Lebanon (Beirut), Lesotho (Maseru), Liberia (Monrovia), Libya (Tripoli), Lithuania (Vilnuis), Luxembourg (Luxembourg), Malawi (Lilongwe), Malaysia (Federal Territory of Kuala Lumpur), Maldives (Malle), Mali (Federal Territory of Kuala Lumpur), Malta (Male), Mauritania (Nouakchott), Mauritius (Port Louis), Mexico (Mexico City), Mongolia (Ulaanbaatar), Bulgaria (Sofia), Burkina Faso (Ouagadougou), Burundi (Gitega), Cambodia (Phnom Penh), Cameroon (Yaoundé), Cape Verde (Praia), Central African Republic (Bangui), Chad (N'Djamena), Chile (Santiago), Colombia (Bogota), Comoros (Moroni), Congo (Kinshasa), Costa Rica (San José), Croatia (Zagreb), Cuba (Havana), Cyprus (Nicosia), Czech Republic (Prague), Denmark (Copenhagen) ,Djibouti (Djibouti City), Dominican Republic (Santo Domingo), DR Congo (Kinshasa), Ecuador (Quito), Egypt (Cairo), El Salvador (San Salvador), Equatorial Guinea (Malabo), Eritrea (Asmara), Estonia (Tallinn)

Technical Features

Type

Bench-top, Discrete, Fully automatic

Vertical, Discrete, Fully automatic

Throughput

200T/H

400T/H

Analysis Method

End-point, Fixed-time, Rate

End-point, kinetic, Two-point

Sample Positions

49 sample positions

120 sample positions

Reagent Positions

56 refrigerated reagent positions

90 pcs (With refrigerated function)

Sample Volume

2ul ~70ul (0.1ul stepping)

2-30ul,0.1"l step

Reagent Volume

R1&R2:20ul ~350ul (1ul stepping)

20-300μl,1μl step

Probe cleaning

Automatic washing both interior and exterior

Automatic washing both interior and exterior

Reagent tray cooling

Continuous 2°C~8°C cooling within 24 hours

Continuous 2°C~8°C cooling within 24 hours

Reaction Time

10 minutes

10 minutes

Temperature Control

37°C±0.1°C, with online software monitor the temperature

37±0.1°C, automatic heating

Cuvettes

120 reusable reaction cuvettes (optical path length 6mm)

90 reusable reaction cuvettes

Mixer probe

After adding reagent and sample, blending immediately

--

Washing

After finish testing, washing probe wash cuvettes automatically

After finish testing, washing probe wash cuvettes automatically

Light Source

12V/30W halogen-tungsten lamp, 2000 hours

Halogen-tungsten lamp

Spectroscopic methods

Post light split detection technique

--

Wavelength Range

340,405,450,510,546,578,630,700nm

340-700nm,8 wavelengths, (4 positions are optional)

Linear Range

0.000~3.000Abs

0.0001Abs

Power Supply

110/220V±10%, 50/60Hz

AC110/220V, ±10%, 50/60Hz,1000VA

Package Size (W*D*H)

1120*730*980mm

1220*1340*890mm

Gross Weight

185kg

200Kg



Technical Features

Type

Bench-top, Discrete, Fully automatic

Vertical, Discrete, Fully automatic

Throughput

200T/H

400T/H

Analysis Method

End-point, Fixed-time, Rate

End-point, kinetic, Two-point

Sample Positions

49 sample positions

120 sample positions

Reagent Positions

56 refrigerated reagent positions

90 pcs (With refrigerated function)

Sample Volume

2ul ~70ul (0.1ul stepping)

2-30ul,0.1"l step

Reagent Volume

R1&R2:20ul ~350ul (1ul stepping)

20-300μl,1μl step

Probe cleaning

Automatic washing both interior and exterior

Automatic washing both interior and exterior

Reagent tray cooling

Continuous 2°C~8°C cooling within 24 hours

Continuous 2°C~8°C cooling within 24 hours

Reaction Time

10 minutes

10 minutes

Temperature Control

37°C±0.1°C, with online software monitor the temperature

37±0.1°C, automatic heating

Cuvettes

120 reusable reaction cuvettes (optical path length 6mm)

90 reusable reaction cuvettes

Mixer probe

After adding reagent and sample, blending immediately

--

Washing

After finish testing, washing probe wash cuvettes automatically

After finish testing, washing probe wash cuvettes automatically

Light Source

12V/30W halogen-tungsten lamp, 2000 hours

Halogen-tungsten lamp

Spectroscopic methods

Post light split detection technique

--

Wavelength Range

340,405,450,510,546,578,630,700nm

340-700nm,8 wavelengths, (4 positions are optional)

Linear Range

0.000~3.000Abs

0.0001Abs

Power Supply

110/220V±10%, 50/60Hz

AC110/220V, ±10%, 50/60Hz,1000VA

Package Size (W*D*H)

1120*730*980mm

1220*1340*890mm

Gross Weight

185kg

200Kg


   