ICU Ventilator Manufacturer,Supplier and Exporter in India

ICU Ventilator

Product Code : SLESPWMFC-11183
Pharmacy Lab Equipment is a leading ICU Ventilator Manufacturer,suppliers and Exporter in India, ICU Ventilator Uruguay (Montevideo), ICU Ventilator Uzbekistan (Tashkent), ICU Ventilator Venezuela (Caracas), ICU Ventilator Vietnam (Hanoi), ICU Ventilator Yemen (Sana'a), ICU Ventilator Zambia (Lusaka), Zimbabwe (Harare), Eswatini (Mbabane) (Lobamba), Ethiopia (Addis Ababa), Fiji (Suva), Gabon (Libreville), Gambia (Banjul), Georgia (Tbilisi), Ghana (Accra), India (Delhi, Mumbai, Kolkatta, Chennai), Indonesia (Jakarta), Iraq (Baghdad), Ivory Coast (Yamoussoukro), Jamaica (Kingston), Jordan (Amman), Kazakhstan (Astana), Kenya (Nairobi), Kiribati (Tarawa), Kosovo (Pristina), Kuwait (Kuwait City), Kyrgyzstan (Bishkek), Laos (Vientiane), Latvia (Riga), Lebanon (Beirut), Lesotho (Maseru), Liberia (Monrovia), Libya (Tripoli), Lithuania (Vilnuis), Luxembourg (Luxembourg), Malawi (Lilongwe), Malaysia (Federal Territory of Kuala Lumpur), Maldives (Malle), Mali (Federal Territory of Kuala Lumpur), Malta (Male), Mauritania (Nouakchott), Mauritius (Port Louis), Mexico (Mexico City), Mongolia (Ulaanbaatar), Bulgaria (Sofia), Burkina Faso (Ouagadougou), Burundi (Gitega), Cambodia (Phnom Penh), Cameroon (Yaoundé), Cape Verde (Praia), Central African Republic (Bangui), Chad (N'Djamena), Chile (Santiago), Colombia (Bogota), Comoros (Moroni), Congo (Kinshasa), Costa Rica (San José), Croatia (Zagreb), Cuba (Havana), Cyprus (Nicosia), Czech Republic (Prague), Denmark (Copenhagen) ,Djibouti (Djibouti City), Dominican Republic (Santo Domingo), DR Congo (Kinshasa), Ecuador (Quito), Egypt (Cairo), El Salvador (San Salvador), Equatorial Guinea (Malabo), Eritrea (Asmara), Estonia (Tallinn)

ICU Ventilator
An Optimal Combination of Invasive and Noninvasive
 
Ventilator :-
As noninvasive ventilation, it is used increasingly in a wide range of clinical situations, we offer a dual solution AN359 which combines the advantages of a flexible noninvasive ventilator with a full-featured invasive ventilator for the ICU 

Ventilation Modes :-
• VCV(A/C), PCV(A/C), PRVC, SIMV(VCV)+PSV, SIMV(PCV)+PSV, SIMV(PRVC)+PSV, SPONT/CPAP +PSV, BIVENT +PSV, NIV/CPAP, NIV-T, NIV-S/T

Parameters :-
• Tidal Volume:20~2000 ml
• Respiration Rate:1~80 bpm
• Tinsp:0.2~9 s
• Tslope:0~2 s
• Tpause:0~4 s
• I:E Ratio:1:10~4:1
• FiO2: Pressure (-20~0 cmH2O, above PEEP), Flow (0.5~20 LPM)
• Trigger Sensitivity:0~35 cmH2O

PEEP:
• P support: 0~70 cmH2O
• Pinsp:5~70 cmH2OMonitoring
• Pressure Value: Ppeak, Pplat, Pmean, Pmin, PEEP
• Volume / Flow Value: Vti, Vte, MV, MVspont
• Time Value:ftotal,fspont, I:E
• Real Time Curves: Pressure-Time, Flow-Time, Volume-Time waveforms, Pressure-Volume, Volume-Flow, Flow-Pressure loops
• Gas Monitoring: FiO2, ETCO2
• Calculated Values: Compliance(C), Resistance(R) MVleak, RSBI, WOB, PEEPi

Alarm:-
• Paw high/low MVe high/low Circuit disconnnect
• FiO2 high/low Inspiration/Expiratory tidal volume low
• High Respiration Rate Apnea AC Failure Nebulizer On
• Low Battery Air /O2 supply down High/Low PEEP
• Leakage out of range Occlusion

Technical Data :-
• Screen:12〞TFT color touch screen (detachable)
• Supply Gas:O2, 0.28~0.6 MPa
• Power Supply:AC100~240 V, 50 Hz/60 Hz
• Communication Interface: RS-232 Port, Nurse call Port, Ethernet Port
• Dimension (Width x Depth x Height):322 mm x 375 mm x 366 mm (Main Unit), 547 mm x 675 mm x 950 mm (Cart)
• Weight:12.5 kg (Main Unit), 25 kg (Cart)


ICU Ventilator
An Optimal Combination of Invasive and Noninvasive
 
Ventilator :-
As noninvasive ventilation, it is used increasingly in a wide range of clinical situations, we offer a dual solution AN359 which combines the advantages of a flexible noninvasive ventilator with a full-featured invasive ventilator for the ICU 

Ventilation Modes :-
• VCV(A/C), PCV(A/C), PRVC, SIMV(VCV)+PSV, SIMV(PCV)+PSV, SIMV(PRVC)+PSV, SPONT/CPAP +PSV, BIVENT +PSV, NIV/CPAP, NIV-T, NIV-S/T

Parameters :-
• Tidal Volume:20~2000 ml
• Respiration Rate:1~80 bpm
• Tinsp:0.2~9 s
• Tslope:0~2 s
• Tpause:0~4 s
• I:E Ratio:1:10~4:1
• FiO2: Pressure (-20~0 cmH2O, above PEEP), Flow (0.5~20 LPM)
• Trigger Sensitivity:0~35 cmH2O

PEEP:
• P support: 0~70 cmH2O
• Pinsp:5~70 cmH2OMonitoring
• Pressure Value: Ppeak, Pplat, Pmean, Pmin, PEEP
• Volume / Flow Value: Vti, Vte, MV, MVspont
• Time Value:ftotal,fspont, I:E
• Real Time Curves: Pressure-Time, Flow-Time, Volume-Time waveforms, Pressure-Volume, Volume-Flow, Flow-Pressure loops
• Gas Monitoring: FiO2, ETCO2
• Calculated Values: Compliance(C), Resistance(R) MVleak, RSBI, WOB, PEEPi

Alarm:-
• Paw high/low MVe high/low Circuit disconnnect
• FiO2 high/low Inspiration/Expiratory tidal volume low
• High Respiration Rate Apnea AC Failure Nebulizer On
• Low Battery Air /O2 supply down High/Low PEEP
• Leakage out of range Occlusion

Technical Data :-
• Screen:12〞TFT color touch screen (detachable)
• Supply Gas:O2, 0.28~0.6 MPa
• Power Supply:AC100~240 V, 50 Hz/60 Hz
• Communication Interface: RS-232 Port, Nurse call Port, Ethernet Port
• Dimension (Width x Depth x Height):322 mm x 375 mm x 366 mm (Main Unit), 547 mm x 675 mm x 950 mm (Cart)
• Weight:12.5 kg (Main Unit), 25 kg (Cart)

   

Office Address

Works: 788, opposite Manji Sahib Gurudawra,
Manmohan Nagar, Ambala, Haryana 134003

[email protected]

+91-70118-22519